An independent measurement of the full neutron dose equivalent can be made by a so-called extended range rem-counter. In this instrument, heavy metal layers complement PE and borated plastic. They increase high-energy sensitivity by neutron spallation. The first documented exemplar of an extended range rem-counter can be found in [17], today a few companies manufacture commercial versions of this or similar dosimeters. Extended rem-counters are both heavier and more expensive than standard instruments.