(This picture shows the circuit after disconnecting the next nearest connector. The test light went out so this means we have found our problem area. The light being off can only mean that the is no more active short and that the problem must be between the connector and the last thing we disconnected. Going through the circuit’s wiring confirms that the short was between the connector and the light bulb from the circuit. When going through the wiring we find that the short to ground was caused by a power and a ground wire having metal to metal contact after the insulation had been chewed off by rodents. The repair for this short simply required to secure the wires away from each other and insulate them once more with electrical tape. You can also spray some anti rodent spray on the wires so they do not go back to chewing them again.)

After the repair the circuit works perfectly and the fuse no longer blows. You should now be able to see how we can use the test light method to find electrical shorts.

The Test Light Method is one of my favorite methods because you don’t have to keep returning to the breaker box or fuse box to reset any circuit breaker, like in the circuit breaker method from before.



Download



Copyright Disclaimer:
This site does not store any files on its server. We only index and link to content provided by other sites. Please contact the content providers to delete copyright contents if any and email us, we'll remove relevant links or contents immediately.