An indirect waste receptor collects drain water from a source and introduces it to the drain system, but it is not connected directly to the wastewater source. Floor drains (above) are common indirect receptors.

Saddle fitting: A saddle fitting is a connection between pipes where a new pipe is attached to an existing pipe by puncturing the existing pipe and clamping the new pipe to the existing pipe. Saddle fittings are sometimes used to tap existing water supply pipes for low volume applications such as refrigerator ice-makers and reverse osmosis water treatment systems. Saddle fittings are prohibited in drainage pipes, but are often found in low volume applications such as reverse osmosis water treatment system discharge tubing connection to trap arms.